中國臺灣Northman調速閥MSF-02T-NO-D12-10代理
中國臺灣Northman調速閥MSF-02T-NO-D12-10代理
中國臺灣北部精機Northman疊加式電控調速閥
MSF-02A-D24-10 MSF-02A-A115-10 MSF-02A-A230-10
MSF-02T-NO-A230-10 MSF-02T-NO-D12-10 MSF-03T-NO-D24-10
MSF-03T-NO-A115-10 MSF-03T-NO-A230-10 MSF-03T-NO-D12-10
SWH-G02-C40BS-D24-20 SWH-G02-C5BS-D24-20 SWH-G02-C6BS-D24-20
中國臺灣Northman疊加式電控單向閥
MSC-02W-230AG-NO-30 MSC-03W-230AG-NO-30 MSC-02A-230AG-NO-30
MSC-03A-230AG-NO-30
中國臺灣北部精機Northman疊加式電控調速閥
MSF-02A-D12-10 MSF-03A-D24-10 MSF-03A-A115-10
中國臺灣Northman電磁閥
SWH-G03-C2-A120-20-LS SWH-G03-C3-A120-20-LS
SWH-G03-C4-A120-20-LS SWH-G03-C40-A120-20-LS
SWH-G03-C5-A120-20-LS SWH-G03-C6-A120-20-LS
SWH-G03-C7-A120-20-LS SWH-G03-C8-A120-20-LS
SWH-G03-C9-A120-20-LS SWH-G03-C8S-A120-20-LS
SWH-G03-D2-A120-20-LS SWH-G03-D3-A120-20-LS
SWH-G03-B2-A120-20-LS SWH-G03-B3-A120-20-LS
SWH-G03-B6-A120-20-LS SWH-G03-B20-A120-20-LS
SWH-G03-C2-D24-20-LS SWH-G03-C3-D24-20-LS
SWH-G03-C4-D24-20-LS SWH-G03-C40-D24-20-LS
SWH-G03-C5-D24-20-LS SWH-G03-C6-D24-20-LS
SWH-G03-C7-D24-20-LS SWH-G03-C8-D24-20-LS
SWH-G03-C9-D24-20-LS SWH-G03-C8S-D24-20-LS
SWH-G03-D2-D24-20-LS SWH-G03-D3-D24-20-LS
SWH-G03-B2-D24-20-LS SWH-G03-B3-D24-20-LS
SWH-G03-B6-D24-20-LS SWH-G03-B20-D24-20-LS
電動閥的操作守則
操作前的準備:
1 操作閥門前,應認真閱讀操作說明。
2 操作前一定要清楚氣體的流向,應注意檢查閥門開閉標志。
3檢查電動閥外觀,看該電動閥門是否受潮,如果有受潮要作干燥處理;如果發現有其他問題要及時處理,不得帶故障操作。
4 對停用3個月以上的電動裝置,啟動前應檢查離合器,確認手柄在手動位置后,再檢查電機的絕緣、轉向及電氣線路。
電動閥門操作注意事項:
1 啟動時,確認離合器手柄在相應位置
2 如果是在控制室控制電動閥,把轉換開關打大REMOTE位置,然后通過SCADA系統控制電動閥的開關。
3如果手動控制,把轉換開關打在LOCAL位置,就地操作電動閥的開關,電動閥開到位或者關到位的時候它會自動停止工作,后把運行轉換開關打到中間位置。
4 采用現場操作閥門時,應監視閥門開閉指示和閥桿運行情況,閥門開閉度要符合要求。
5 采用現場操作全關閉閥門時,在閥門關到位前,應停止電動關閥,改用微動將閥門關到位。
6 對行程和超扭矩控制器整定后的閥門,*全開或全關閥門時,應注意監視其對行程的控制情況,如閥門開關到位置沒有停止的,應立即手動緊急停機。
7 在開、閉閥門過程中,發現信號指示燈指示有誤、閥門有異常響聲時,應及時停機檢查。
8 操作成功后應關閉電動閥門的電源。
9 同時操作多個閥門時,應注意操作順序,并滿足生產工藝要求。
10開啟有旁通閥門的較大口徑閥門時,若兩端壓差較大,應先打開旁通閥調壓,再開主閥:主閥打開后,應立即關閉旁通閥。
11 收發清管球(器)時,其經過的球閥必須全開。
12 操作球閥、閘閥、截止閥、蝶閥只能全開或全關,嚴禁作調節用。
13 操作閘閥、截止閥和平板閥過程中,當關閉或開啟到上死點或下死點時,應回轉1/2~1圈。