熱賣德國PTL灼熱絲測試儀T03.14
熱賣德國PTL灼熱絲測試儀T03.14
PTL Glow-Wire Test Apparatus | ||||||||||||||||||||||||||||||||||
to determine the fire resistance by the fire hazard test. | ||||||||||||||||||||||||||||||||||
Test apparatus according to | IEC 60695-2-10 | :2000-10, | ||||||||||||||||||||||||||||||||
for glow-wire flammability tests for end-products (IEC 60695-2-11), for glow-wire flammability index tests method for materials GWFI (IEC 60695-2-12) and for glow-wire ignitability tests for materials GWIT (IEC 60695-2-12). | ||||||||||||||||||||||||||||||||||
Standard outfit: | ||||||||||||||||||||||||||||||||||
1 | glow-wire loop of nickel-chromium, with clamping mechanism, | |||||||||||||||||||||||||||||||||
1 | carriage to be moved by hand, with multiple adjustable holding device for the specimen, | |||||||||||||||||||||||||||||||||
1 | rail system with ground running surfaces, | |||||||||||||||||||||||||||||||||
1 | pair of fine ropes with weights for the contact force of 1 N, | |||||||||||||||||||||||||||||||||
1 | indicating device for the depth of penetration, with maximum pointer and stop, | |||||||||||||||||||||||||||||||||
1 | scale to measure the flame height, multiple adjustable, | |||||||||||||||||||||||||||||||||
1 | high current isolating transformer to heat the wire loop, with series connected vari-able ratio transformer, to set the temperature up to 960 °C, | |||||||||||||||||||||||||||||||||
1 | miniature jacket thermocouple type K (NiCr/NiAl), with plug almost free from thermo-electric voltage and with compensating lead, | |||||||||||||||||||||||||||||||||
1 | temperature indicating instrument to indicate the temperature of the glow-wire loop, with digital display, measuring range 0...1000 °C, class 0.5, can be readjusted, with compensation of the ambient temperature, | |||||||||||||||||||||||||||||||||
1 | housing, desk shaped, with all necessary electrical components, with safety switch and 2 keys. | |||||||||||||||||||||||||||||||||
Design: | ||||||||||||||||||||||||||||||||||
Testing device mounted on the housing of sheet steel, papyrus-white structure varnished, plan dimensions approx. 400 mm x 400 mm, total height approx. 570 mm, carriage and specimen holding device of corrosion-protected materials, | ||||||||||||||||||||||||||||||||||
delivery including foil of fine silver 99.8 %, 0.06 mm thick, for calibration of the temperature indicating instrument, board of pine wood, 10 mm thick, wrapping tissue and mains connection cord set, | ||||||||||||||||||||||||||||||||||
for connection to A.C. 230 V, 50 to 60 Hz, | ||||||||||||||||||||||||||||||||||
Glow-Wire Test Apparatus 14 | Besl-Nr.: | T 03.14 | ||||||||||||||||||||||||||||||||
Alternatively: | ||||||||||||||||||||||||||||||||||
The Glow-Wire Test Apparatus 35 is equal to the basic model T 03.14 however it is fitted with the following additional outfit: | ||||||||||||||||||||||||||||||||||
Motor Drive for moving the specimen to the wire loop, and for returning to the starting position. As soon as the specimen contacts the loop, a coupling releases the carriage. After an operation time of exactly 30 seconds, the carriage is automatically returned. The test results are better reproducible, and the laboratory technician's attention is not diverted during the testing procedure by having to do various operation tasks. He can fully concentrate on the observation of the specimen. |